Shopping Cart
Go To Cart
Go To Cart Continue Shopping

Tax included. Shipping calculated at checkout.

No Image

M2XH 0,6/1 kV (NOFI) 16 x 1.50

Product Code:
aq_14400
No Price
ABSBVDNVCRSLloydsRinaTürk Loyduflammwidrig nach IEC 60332-1-2UV-beständig

Product Relations

ProductTypePrice
M2XH (NOFI) 0,6/1 kV 16 x 1,5 bk flex cl.5M2XH (NOFI) 0,6/1 kV 16 x 1,5 bk flex cl.5inheritance-
M2XH (NOFI) 0,6/1 kV 16 G 1,5 bk flex cl.5M2XH (NOFI) 0,6/1 kV 16 G 1,5 bk flex cl.5inheritance-
ERP
BKM000023sw
BKM0000494.00
BKM00001085444995
BKM000011230.40 kg
BKM0000120.00
BKM000018405.00 kg
Aussenmasse (ERP)Kl. 5
BKM00016898
BKM00016965
core number16
core number (ERP)16
Nominal conductor cross-section 1.50
Nominal conductor cross-section (ERP) 1.50
Other
Certificate marine cable ABS Ja
Certificate marine cable BV Ja
Certificate marine cable NipponNein
UV-resistant Ja
Certificate marine cable DNV Ja
Certificate marine cable CRSJa
Core insulation BK000065
Certificate marine cable Lloyds register Ja
Core nameBK000073
Certificate marine cable RinaJa
Certificate marine cable Türk LoyduJa
FillerNein
Test voltage3.50
Lead jacketNein
drain wireNein
Shield under core insulationBK000001
Shield coverage 0
Outer jacket colorBK000072
Tests and material according to IEC 60092-376Ja
Low smoke according to EN IEC 61034-1Ja
Ozone resistant according to EN IEC 60811-403Ja
UV resistant according to EN 50289-4-17 A-B, ISO 4892-2-3Ja
Cable materialBK000062
Insulation integrity in the event of fire according to IEC 60331-21Nein
Insulation integrity in the event of fire according to IEC 60331-1-2Nein
Screen over rope element BK000001
Screen over rope BK000109
Outer jacket materialBK000094
Conductor class BK000138
Fiber optic elementsNein
ReinforcementBK000001
Temperature range max., permanently installed90
Temperature range min., permanently installed-40
Construction BK000035
General requirements and tests according to VG 95218-2Nein
Nominal current according to VG 95218-5Nein
Shielding attenuation measurement according to DIN EN 50147-1Nein
Inner conductive layerNein
Screen longitudinally waterproofNein
Rated voltage Uo0.60
ShieldingNein
Longitudinally watertight conductorNein
suitable for installation in the groundNein
Stranding BK000160
Protective coverBK000001
with gn/ye protective conductorJa
With rodent protectionNein
conductive coatingNein
oil resistant according to EN IEC 60811-404Nein
Cable cross waterproofJa
Specification of conductor insulation BK000169
Specification of jacket materialBK000003
Outer jacket reinforcementBK000001
Cable geometryBK000068
Core identification according to HD 3080 S2Nein
certified for marine applicationsJa
suitable as medium voltage cable Nein
suitable as high voltage cable Nein
certified for airport lighting cableNein
Functional maintenance according to EN 50200 annex ENein
flame retardant according to IEC 60332-1-2Ja
flame retardant according to IEC 60332-3-21 (Cat A F/R)Nein
flame retardant according to IEC 60332-3-22 (Cat A)Ja
flame retardant according to IEC 60332-3-23 (Cat B)Nein
flame retardant according to IEC 60332-3-24 (Cat C)Nein
flame retardant according to IEC 60332-3-25 (Cat D)Nein
Functional maintenance according to EN 50200BK000001
Insulation maintenance according to DIN VDE 0472-8154BK000001
Functional maintenance according to DIN 4102-12BK000001
Functional maintenance according to BS 6387 CWZNein
Functional maintenance according to BS 8434-2Nein
Functional maintenance according to BS 8491BK000123
EF000024Ja
EF000061EV000157
EF000067EV000207
EF001027Nein
EF001029Nein
EF001618EV000206
EF001622EV000138
EF001624EV003606
EF001625EV001108
EF001632EV004201
EF001638Nein
EF001700Nein
EF001704Nein
EF0017900.60
EF001791Nein
EF001795Nein
EF003689Nein
EF003802EV006289
EF0038030.00
EF007468Ja
EF007960Nein
EF008389Nein
EF009770Nein
EF011012Ja
EF011805EV006313
EF011806BK000003
EF013532EV000167
EF013766Nein
EF013772Ja
EF013773Nein
EF013774Nein
EF013775Nein
EF0138010.00
EF016490Nein
EF016492Ja
EF016493Nein
EF016494Ja
EF016495Nein
EF016496Nein
EF016497Nein
EFUK0001Nein
EFUK0004Nein

ARTIKELBESCHREIBUNG

BESONDERHEITEN

Zulassung Schiffskabel ABS
Zulassung Schiffskabel BV
Zulassung Schiffskabel DNV
Zulassung Schiffskabel CRS
Zulassung Schiffskabel Lloyds Register
Zulassung Schiffskabel Rina
Zulassung Schiffskabel Türk Loydu
Raucharm
flammwidrig nach IEC 60332-1-2
UV-beständig
mit GN/GE-Schutzleiter

Product Documents