Shopping Cart
Go To Cart
Go To Cart Continue Shopping

Tax included. Shipping calculated at checkout.

No Image
Product Code:
ug_127
No Price
flammwidrig nach IEC 60332-1-2

Product Relations

ProductTypePrice
RD-Y(ST)Y 1 x 2 x 0.50RD-Y(ST)Y 1 x 2 x 0.50inheritance-
RD-Y(ST)Y 20 x 2 x 0.50RD-Y(ST)Y 20 x 2 x 0.50inheritance-
RD-Y(ST)Y 24 x 2 x 0.50RD-Y(ST)Y 24 x 2 x 0.50inheritance-
RD-Y(ST)Y 28 x 2 x 0.50RD-Y(ST)Y 28 x 2 x 0.50inheritance-
RD-Y(ST)Y 32 x 2 x 0.50RD-Y(ST)Y 32 x 2 x 0.50inheritance-
RD-Y(ST)Y 36 x 2 x 0.50RD-Y(ST)Y 36 x 2 x 0.50inheritance-
RD-Y(ST)Y 40 x 2 x 0.50RD-Y(ST)Y 40 x 2 x 0.50inheritance-
RD-Y(ST)Y 44 x 2 x 0.50RD-Y(ST)Y 44 x 2 x 0.50inheritance-
RD-Y(ST)Y 48 x 2 x 0.50RD-Y(ST)Y 48 x 2 x 0.50inheritance-
RD-Y(ST)Y 52 x 2 x 0.50RD-Y(ST)Y 52 x 2 x 0.50inheritance-
RD-Y(ST)Y 56 x 2 x 0.50RD-Y(ST)Y 56 x 2 x 0.50inheritance-
RD-Y(ST)Y 60 x 2 x 0.50RD-Y(ST)Y 60 x 2 x 0.50inheritance-
RD-Y(ST)Y 64 x 2 x 0.50RD-Y(ST)Y 64 x 2 x 0.50inheritance-
RD-Y(ST)Y 80 x 2 x 0.50RD-Y(ST)Y 80 x 2 x 0.50inheritance-
RD-Y(ST)Y 96 x 2 x 0.50RD-Y(ST)Y 96 x 2 x 0.50inheritance-
RD-Y(ST)Y 2 x 2 x 1.00RD-Y(ST)Y 2 x 2 x 1.00inheritance-
RD-Y(ST)Y 4 x 2 x 1.00RD-Y(ST)Y 4 x 2 x 1.00inheritance-
RD-Y(ST)Y 8 x 2 x 1.00RD-Y(ST)Y 8 x 2 x 1.00inheritance-
RD-Y(ST)Y 12 x 2 x 1.00RD-Y(ST)Y 12 x 2 x 1.00inheritance-
RD-Y(ST)Y 16 x 2 x 1.00RD-Y(ST)Y 16 x 2 x 1.00inheritance-
RD-Y(ST)Y 20 x 2 x 1.00RD-Y(ST)Y 20 x 2 x 1.00inheritance-
RD-Y(ST)Y 24 x 2 x 1.00RD-Y(ST)Y 24 x 2 x 1.00inheritance-
RD-Y(ST)Y 32 x 2 x 1.00RD-Y(ST)Y 32 x 2 x 1.00inheritance-
RD-Y(ST)Y 40 x 2 x 1.00RD-Y(ST)Y 40 x 2 x 1.00inheritance-
RD-Y(ST)Y 48 x 2 x 1.00RD-Y(ST)Y 48 x 2 x 1.00inheritance-
RD-Y(ST)Y 2 x 2 x 0.50RD-Y(ST)Y 2 x 2 x 0.50inheritance-
RD-Y(ST)Y 4 x 2 x 0.50RD-Y(ST)Y 4 x 2 x 0.50inheritance-
RD-Y(ST)Y 8 x 2 x 0.50RD-Y(ST)Y 8 x 2 x 0.50inheritance-
RD-Y(ST)Y 12 x 2 x 0.50RD-Y(ST)Y 12 x 2 x 0.50inheritance-
RD-Y(ST)Y 16 x 2 x 0.50RD-Y(ST)Y 16 x 2 x 0.50inheritance-
RD-Y(ST)Y 80 x 2 x 1.00RD-Y(ST)Y 80 x 2 x 1.00inheritance-
ERP
BKM000023gr
BKM00001085444995
BKM00016810
Other
UV-resistant Nein
Core insulation BK000066
Core nameBK000073
Cable typeBK000064
drain wireJa
Rated voltage U300.00
Outer jacket colorBK000080
CategorieBK000001
Cable materialBK000062
Screen over rope element BK000109
Screen over rope BK000109
Outer jacket materialBK000066
Conductor class BK000137
ReinforcementBK000001
Temperature range max., moving50
Temperature range min., moving-5
Temperature range max., permanently installed70
Temperature range min., permanently installed-40
suitable for installation in the groundNein
halogen free according to EN IEC 60754-2Nein
low smoke according to EN IEC 61034-2Nein
Stranding BK000207
With rodent protectionNein
oil resistant according to EN IEC 60811-404Nein
longitudinally watertightNein
Cable cross waterproofNein
Bending factor, moving7.50
Outer jacket reinforcementBK000064
Core identification according to HD 3080 S2Nein
suitable as a teleohne cable Nein
suitable as computer data cableNein
suitable as signal cable Nein
certified for marine applicationsNein
flame retardant according to IEC 60332-1-2Ja
flame retardant according to IEC 60332-3-21 (Cat A F/R)Nein
flame retardant according to IEC 60332-3-22 (Cat A)Nein
flame retardant according to IEC 60332-3-23 (Cat B)Nein
flame retardant according to IEC 60332-3-24 (Cat C)Nein
flame retardant according to IEC 60332-3-25 (Cat D)Nein
halogen free according to EN IEC 60754-1Nein
halogen free according to EN IEC 60754-3Nein
Functional maintenance according to IEC 60331-23Nein
suitable as security alarm cable Nein
DuplexNein
Functional maintenance according to DIN 4102-12BK000001
EF000024Nein
EF000061EV000163
EF000067EV000207
EF000081EV000154
EF001029Ja
EF001615300.00
EF001618EV000270
EF001622EV000138
EF001623EV003606
EF001624EV003606
EF001625EV000163
EF001632EV004200
EF003689Nein
EF003792Nein
EF003802EV010565
EF007960Nein
EF009770Nein
EF013440EV000154
EF013772Nein
EF016492Ja
EF016498Nein
EF016500Nein
EF016619Nein
EF023003Nein

ARTIKELBESCHREIBUNG

Leittechnikkabel zum Einsatz in der Mess-, Steuer- und Regeltechnik sowie in Kraftwerks- und Industrieanlagenleitständen für feste Verlegung in trockenen und feuchten Räumen, im Freien, jedoch nicht im Erdreich. Ein statischer Schirm schützt die Übertragungskreise gegen äußere elektrische Störfelder. Maxi-termi-point-tauglich.

BESONDERHEITEN

flammwidrig nach IEC 60332-1-2

Product Description

Leittechnikkabel zum Einsatz in der Mess-, Steuer- und Regeltechnik sowie in Kraftwerks- und Industrieanlagenleitständen für feste Verlegung in trockenen und feuchten Räumen, im Freien, jedoch nicht im Erdreich. Ein statischer Schirm schützt die Übertragungskreise gegen äußere elektrische Störfelder. Maxi-termi-point-tauglich.

Product Documents