Shopping Cart

- Product Code:
- ug_181
Product Relations
| ERP | |
|---|---|
| BKM000023 | gr |
| BKM000010 | 85444920 |
| BKM000168 | 100 |
| Other | |
| Certificate marine cable ABS | Nein |
| Certificate marine cable BV | Nein |
| Certificate marine cable Nippon | Nein |
| UV-resistant | Nein |
| Certificate marine cable DNV | Nein |
| Certificate marine cable CRS | Nein |
| Core insulation | BK000064 |
| Certificate marine cable Lloyds register | Nein |
| Core name | BK000161 |
| Certificate marine cable Rina | Nein |
| Certificate marine cable Türk Loydu | Nein |
| Cable type | BK000064 |
| drain wire | Ja |
| Categorie | BK000001 |
| Cable material | BK000062 |
| Screen over rope element | BK000001 |
| Screen over rope | BK000109 |
| Outer jacket material | BK000064 |
| Conductor class | BK000136 |
| Reinforcement | BK000001 |
| Temperature range max., moving | 50 |
| Temperature range min., moving | -5 |
| Temperature range max., permanently installed | 70 |
| Temperature range min., permanently installed | -30 |
| suitable for installation in the ground | Nein |
| halogen free according to EN IEC 60754-2 | Nein |
| low smoke according to EN IEC 61034-2 | Ja |
| Stranding | BK000160 |
| With rodent protection | Nein |
| oil resistant according to EN IEC 60811-404 | Nein |
| longitudinally watertight | Nein |
| Cable cross waterproof | Nein |
| Bending factor, moving | 7.50 |
| Bending factor, permanently installed | 2.50 |
| Outer jacket reinforcement | BK000064 |
| Core identification according to HD 3080 S2 | Nein |
| suitable as a teleohne cable | Ja |
| suitable as computer data cable | Nein |
| suitable as signal cable | Ja |
| certified for marine applications | Nein |
| flame retardant according to IEC 60332-1-2 | Ja |
| flame retardant according to IEC 60332-3-21 (Cat A F/R) | Nein |
| flame retardant according to IEC 60332-3-22 (Cat A) | Nein |
| flame retardant according to IEC 60332-3-23 (Cat B) | Nein |
| flame retardant according to IEC 60332-3-24 (Cat C) | Ja |
| flame retardant according to IEC 60332-3-25 (Cat D) | Nein |
| halogen free according to EN IEC 60754-1 | Ja |
| halogen free according to EN IEC 60754-3 | Nein |
| Functional maintenance according to IEC 60331-23 | Nein |
| suitable as security alarm cable | Nein |
| Duplex | Nein |
| Functional maintenance according to DIN 4102-12 | BK000001 |
| BKM000484 | BD = grau, BMK = rot |
| EF000024 | Nein |
| EF000061 | EV000154 |
| EF000067 | EV006290 |
| EF000081 | EV000154 |
| EF001029 | Ja |
| EF001622 | EV000138 |
| EF001624 | EV003606 |
| EF001625 | EV000154 |
| EF001632 | EV004199 |
| EF003689 | Nein |
| EF003792 | Nein |
| EF003799 | Ja |
| EF003802 | EV006289 |
| EF007960 | Nein |
| EF009770 | Nein |
| EF013766 | Nein |
| EF013768 | Ja |
| EF013769 | Nein |
| EF013770 | Ja |
| EF013772 | Nein |
| EF016492 | Ja |
| EF016493 | Nein |
| EF016494 | Nein |
| EF016495 | Nein |
| EF016496 | Ja |
| EF016497 | Nein |
| EF016498 | Ja |
| EF016500 | Nein |
| EF016619 | Nein |
| EF017089 | Nein |
| EF023003 | Nein |
ARTIKELBESCHREIBUNG
Flexible Datenübertragungs-, Steuer- und Verbindungsleitung in der Mess-, Steuer- und Regeltechnik, in Gegensprechanlagen, im Maschinen-, Werkzeug- und Anlagenbau sowie in der Elektronik, insbesondere dort, wo kleine Abmessungen verlangt werden. Für Verlegung in Gebäuden, in denen die Freisetzung von Halogenen im Brandfall vermieden werden muss, in trockenen und feuchten Räumen, im oder unter Putz, jedoch nicht im Freien oder im Erdreich.
BESONDERHEITEN
Product Description
Flexible Datenübertragungs-, Steuer- und Verbindungsleitung in der Mess-, Steuer- und Regeltechnik, in Gegensprechanlagen, im Maschinen-, Werkzeug- und Anlagenbau sowie in der Elektronik, insbesondere dort, wo kleine Abmessungen verlangt werden. Für Verlegung in Gebäuden, in denen die Freisetzung von Halogenen im Brandfall vermieden werden muss, in trockenen und feuchten Räumen, im oder unter Putz, jedoch nicht im Freien oder im Erdreich.