Shopping Cart
Go To Cart
Go To Cart Continue Shopping

Tax included. Shipping calculated at checkout.

No Image
Product Code:
ug_29
No Price
flammwidrig nach IEC 60332-1-2

Product Relations

ProductTypePrice
N2XSY   6/10kV 1 x 400 RM/35N2XSY 6/10kV 1 x 400 RM/35inheritance-
N2XSY   6/10kV 1 x 150 RM/25N2XSY 6/10kV 1 x 150 RM/25inheritance-
N2XSY   6/10kV 3 x 35 RM/16N2XSY 6/10kV 3 x 35 RM/16inheritance-
N2XSY   6/10kV 1 x 25 RM/16N2XSY 6/10kV 1 x 25 RM/16inheritance-
N2XSY   6/10kV 1 x 35 RM/16N2XSY 6/10kV 1 x 35 RM/16inheritance-
N2XSY   6/10kV 1 x 50 RM/16N2XSY 6/10kV 1 x 50 RM/16inheritance-
N2XSY   6/10kV 1 x 70 RM/16N2XSY 6/10kV 1 x 70 RM/16inheritance-
N2XSY   6/10kV 1 x 95 RM/16N2XSY 6/10kV 1 x 95 RM/16inheritance-
N2XSY   6/10kV 1 x 120 RM/16N2XSY 6/10kV 1 x 120 RM/16inheritance-
N2XSY   6/10kV 1 x 150 RM/16N2XSY 6/10kV 1 x 150 RM/16inheritance-
N2XSY   6/10kV 1 x 185 RM/16N2XSY 6/10kV 1 x 185 RM/16inheritance-
N2XSY   6/10kV 1 x 185 RM/25N2XSY 6/10kV 1 x 185 RM/25inheritance-
N2XSY   6/10kV 1 x 240 RM/16N2XSY 6/10kV 1 x 240 RM/16inheritance-
N2XSY   6/10kV 1 x 240 RM/25N2XSY 6/10kV 1 x 240 RM/25inheritance-
N2XSY   6/10kV 1 x 300 RM/25N2XSY 6/10kV 1 x 300 RM/25inheritance-
N2XSY   6/10kV 1 x 500 RM/35N2XSY 6/10kV 1 x 500 RM/35inheritance-
N2XSY   6/10kV 1 x 500 RM/70N2XSY 6/10kV 1 x 500 RM/70inheritance-
ERP
BKM000023rt
BKM00001085446010
BKM00016830
Other
UV-resistant Nein
Core insulation BK000167
Core nameBK000001
Conductor category product groupBK000137
drain wireNein
Inner jacket Nein
Outer jacket colorBK000074
Cable materialBK000062
Outer jacket materialBK000066
Layer jacketNein
Fiber optic elementsNein
ReinforcementBK000001
Temperature range max., moving70
Temperature range min., moving-5
Temperature range max., permanently installed70
Temperature range min., permanently installed-5
Outer conductive layerNein
Screen longitudinally waterproofNein
Rated voltage Uo6.00
ShieldingNein
Longitudinally watertight conductorNein
halogen free according to EN IEC 60754-2Nein
low smoke according to EN IEC 61034-2Nein
Conductor temperure 90
Protective coverBK000001
With rodent protectionNein
conductive coatingNein
Conductor surfaceBK000091
Specification of conductor insulation BK000064
Specification of jacket materialBK000064
Outer jacket reinforcementBK000001
Core identification according to HD 3080 S2Nein
suitable as installation cable Nein
certified for marine applicationsNein
suitable as medium voltage cable Nein
certified for airport lighting cableNein
Functional maintenance according to EN 50200 annex ENein
flame retardant according to IEC 60332-1-2Ja
flame retardant according to IEC 60332-3-21 (Cat A F/R)Nein
flame retardant according to IEC 60332-3-22 (Cat A)Nein
flame retardant according to IEC 60332-3-23 (Cat B)Nein
flame retardant according to IEC 60332-3-24 (Cat C)Nein
flame retardant according to IEC 60332-3-25 (Cat D)Nein
halogen free according to EN IEC 60754-1Nein
Functional maintenance according to IEC 60331-1BK000001
Functional maintenance according to IEC 60331-2BK000001
Functional maintenance according to IEC 60331-3BK000001
Functional maintenance according to EN 50200BK000001
Insulation maintenance according to DIN VDE 0472-8154BK000001
Functional maintenance according to DIN 4102-12BK000001
Functional maintenance according to BS 6387 CWZNein
Functional maintenance according to BS 8434-2Nein
Functional maintenance according to BS 8491BK000123

ARTIKELBESCHREIBUNG

Zur Verlegung im Freien, in der Erde, in Innenräumen und Kabelkanälen, in Kraftwerken und in Industrie- und Schaltanlagen. Die Kabel sind für hohe thermische Belastungen im Betrieb ausgelegt. Aufgrund der guten Verlegeeigenschaften lassen sich die Kabel auch bei schwierigen Trassenführungen leicht verlegen. Die DIN-VDE 0298 Teil 1 ist bei der Verlegung zu beachten.

BESONDERHEITEN

flammwidrig nach IEC 60332-1-2

Product Description

Zur Verlegung im Freien, in der Erde, in Innenräumen und Kabelkanälen, in Kraftwerken und in Industrie- und Schaltanlagen. Die Kabel sind für hohe thermische Belastungen im Betrieb ausgelegt. Aufgrund der guten Verlegeeigenschaften lassen sich die Kabel auch bei schwierigen Trassenführungen leicht verlegen. Die DIN-VDE 0298 Teil 1 ist bei der Verlegung zu beachten.

Product Documents