Shopping Cart

- Product Code:
- ug_176
Product Relations
| ERP | |
|---|---|
| BKM000023 | or |
| BKM000010 | 85444991 |
| BKM000168 | 50 |
| Other | |
| UV-resistant | Nein |
| Core insulation | BK000064 |
| Core name | BK000073 |
| Conductor category product group | Kl.1 = eindrähtig, ab 25mm² Kl.2 = mehrdrähtig |
| drain wire | Nein |
| Inner jacket | Nein |
| Outer jacket color | BK000077 |
| Cable material | BK000062 |
| Outer jacket material | BK000064 |
| Layer jacket | Nein |
| Fiber optic elements | Nein |
| Reinforcement | BK000001 |
| Temperature range max., moving | 90 |
| Temperature range min., moving | -5 |
| Temperature range max., permanently installed | 90 |
| Temperature range min., permanently installed | -30 |
| Outer conductive layer | Nein |
| Screen longitudinally waterproof | Nein |
| Rated voltage Uo | 0.60 |
| Shielding | Nein |
| Longitudinally watertight conductor | Nein |
| halogen free according to EN IEC 60754-2 | Ja |
| low smoke according to EN IEC 61034-2 | Ja |
| Conductor temperure | 90 |
| Protective cover | BK000001 |
| With rodent protection | Nein |
| conductive coating | Nein |
| Conductor surface | BK000091 |
| Specification of conductor insulation | BK000064 |
| Specification of jacket material | BK000064 |
| Outer jacket reinforcement | BK000001 |
| Core identification according to HD 3080 S2 | Nein |
| suitable as installation cable | Nein |
| certified for marine applications | Nein |
| suitable as medium voltage cable | Nein |
| certified for airport lighting cable | Nein |
| Functional maintenance according to EN 50200 annex E | Nein |
| flame retardant according to IEC 60332-1-2 | Nein |
| flame retardant according to IEC 60332-3-21 (Cat A F/R) | Nein |
| flame retardant according to IEC 60332-3-22 (Cat A) | Nein |
| flame retardant according to IEC 60332-3-23 (Cat B) | Nein |
| flame retardant according to IEC 60332-3-24 (Cat C) | Ja |
| flame retardant according to IEC 60332-3-25 (Cat D) | Nein |
| halogen free according to EN IEC 60754-1 | Ja |
| Functional maintenance according to IEC 60331-1 | BK000253 |
| Functional maintenance according to IEC 60331-2 | BK000001 |
| Functional maintenance according to IEC 60331-3 | BK000001 |
| Functional maintenance according to EN 50200 | BK000001 |
| Insulation maintenance according to DIN VDE 0472-8154 | BK000145 |
| Functional maintenance according to DIN 4102-12 | BK000001 |
| Functional maintenance according to BS 6387 CWZ | Nein |
| Functional maintenance according to BS 8434-2 | Nein |
| Functional maintenance according to BS 8491 | BK000123 |
ARTIKELBESCHREIBUNG
Für feste Verlegung in trockenen und feuchten Räumen auf, im und unter Putz sowie im Mauerwerk und Beton. Die Kabel sind auch für die Verwendung im Freien und Erdreich bei einer Verlegung in Rohren geeignet. Darüber hinaus gilt DIN VDE 0298 Teil 1 und 2. Zulässige Betriebstemperatur am Leiter: +90 °C. Die Kabel erfüllen die Bedingungen der Prüfung auf Isolationserhalt nach DIN VDE 0472 Teil 814/8.83 über 180 min und nach IEC Publication 331, first edition. Funktionserhalt > 30 Min. bzw > 90 Min. nach DIN 4102 Teil 12, entsprechend VDE 0107 und 0108.
BESONDERHEITEN
Product Description
Für feste Verlegung in trockenen und feuchten Räumen auf, im und unter Putz sowie im Mauerwerk und Beton. Die Kabel sind auch für die Verwendung im Freien und Erdreich bei einer Verlegung in Rohren geeignet. Darüber hinaus gilt DIN VDE 0298 Teil 1 und 2. Zulässige Betriebstemperatur am Leiter: +90 °C. Die Kabel erfüllen die Bedingungen der Prüfung auf Isolationserhalt nach DIN VDE 0472 Teil 814/8.83 über 180 min und nach IEC Publication 331, first edition. Funktionserhalt > 30 Min. bzw > 90 Min. nach DIN 4102 Teil 12, entsprechend VDE 0107 und 0108.